2020-11-05
installation instructions
Tools needed
• Utility knife & straight edge
• Measuring tape
• Dead Blow Mallet
• Shears for cutting around irregular
shaped objects (pipes)
• 8mm spacers
• Pencil
• Tapping Block
Planks needed to complete your project. Measure and multiply the length & width of your
room. If the room has alcoves or offsets, measure these separately. This will give you the square meters of the room. Purchase a minimum of 10% extra to cover mistakes, trimming and for future needs andor replacement. Most installations require about 10% overage. However this can vary depending upon the room size and layout.
CLICKinstallation limitations:
Do not installCLICKover carpet or any foam underlayment. This product is not recommended for any outside use, sunrooms/solariums, saunas, seasonal porches, camping trailers, boats, RV's or rooms that have a potential of flooding. Protect CLICK from direct sunlight using window treatments or UV tinting on window.CLICKis not intended for use on vertical surfaces.
Three-season rooms (Residential Applications only)
CLICK click is permitted in residential “three-season rooms” when installed in strict compliance with the instructions listed below.
. Maximum room size of 500Sq.Ft.(46.5Sq.m)
.Room must be completely enclosed(roof,floor,walls and windows) and not exposed to any outside elements.
.Installation must occur at room temperature between 50ºF and 100ºF(10ºC and 38ºC)
. Allow 10mm expansion space around perimeter and all fixed objects.
. Do not put extremely heavy objects on the paved floor
CLICKis a floating floor system — i.e. must be free to expand and contract. Do not glue, nail, screw or fasten to substrate. Install cabinetry, island and peninsula counters, vanities, tubs, and showers first. Then install
CLICKaround them. Skirtings fitted extremely tightly/glued to the floor may inhibit expansion.
ConditionCLICKprior to installation
The Installation ofCLICKdoes not require acclimation. However we recommend installation in rooms with temperatures between 10°C & 38°C. Product should be stored horizontally in a dry area away from direct sunlight. Do not leave next to heat or cooling ducts. Ensure that all trades have been completed to eliminate dry wall dust, paints, etc.
NOTE: IfCLICKis subjected to extreme hot or cold temperatures prior to installation it may make the
product more difficult to install or cause damage to the locking system. Allow the product to reach room temperature before installation.
KEY INSTALLATION TIPS
Interior Environmental Conditions 10°C to 38°C & 40% to 60% relative humidity
Acclimation Not Required
Subfloor Flatness Tolerances 6.35mm over 3.05m or 3.18mm over 1.83m
Vapor Barrier (6 mil poly) Not Required
Underlayment Pad Required NO –CLICK
includes pre-attached pad
Radiant Heated Floors Must be cast 12.7mm below subfloor.
Substrate surface temperature should
never exceed 30° C
Perimeter Expansion 8mm gap around walls, space requirements
heavy fixed objects (cabinetry)
Glue Down Installation NOT RECOMMENDED – Voids the warranty
Connection Type I4FJoints (Click)
Free Floating Floor Yes. DO NOT screw or nail moldings, transitions, cabinetry or vents through ANYCLICKflooring Temp range before, during 10° C to 38° C.
and after installation: After installation temps should stay between 7° C to 50° C
Interior Product Only Yes. See limitations/exclusions below Storage Horizontally
Expansion Space Yes. For room perimeters and fixed objects please leave 8mm optimum space
Expansion Break An expansion break is required for every 20m x 20m area ofCLICKflooring installed. If exposed to high temperatures/sunlight,
Floor Flatness Tolerances 6mm over 3.05m. Use floor leveler when exceeding tolerance.
Special Tools Required Yes. Utility knife and straight edge, measuring tape, Deadblow mallet(to tap and lock plank seams), shears, tapping block, pencil and 8mm spacers
Moisture Reading Guidelines; Based on Tramex Concrete Moisture Encounter Plus Meter
OVER CONCRETE (scale 0 to 6%)
Scale 0% to 4% No moisture barrier
Scale 5% to 6% Use 150 micron poly moisture barrier
Scale over 6% Seal concrete with waterproofing agent
Moisture Reading Guidelines; Never use 6 mil poly over wooden subfloors
OVER WOOD
Scale 0 to 13% OK to install. Do not install above 13% moisture levels
Primer Over Wooden Subfloors No
Basement Proofer over Concrete No
Moisture Barrier (6 mil poly) Yes above 5% only
Installs Over Radiant Flooring Yes. Electric or hydronic approved — best practice recessed
min 12.7mm below finished floor.
Substrate surface temperature should never exceed 30° C
Suspended Wood Floors Yes. 457mm minimum well ventilated crawl space
Use moisture barrier over ground/dirt
Especially for mobile home installations
Foam/Cushioned Underlayment No. Voids warranty if used in any application
Approved Subfloors - See Below Must be smooth, solid, dry and no deflection
Wood Yes. Solid, engineered, parquet, but not woods installed over concrete.
Plywood Yes. OSB & particleboard are approved forCLICKproducts only
Luan is approved for all products
Vinyl Yes. install over 1 layer only: Vinyl, linoleum, VCT, LVT, and Peel & Stick
Concrete Yes. Sealed, unsealed, poured in place gypsum.
On grade or below grade (see moisture guidelines)
Plank (Stone) Yes. Ceramic, Terrazzo, stone plank
(grout lines of less than 6mm is optimum)
Dricore xl Yes
Subfloors Not Approved Carpet (any type), foam underlayment, cushioned back vinyl,
rubber, cork, free floating floors
Subfloor Approved Products Primer - Custom Building Products Level Quik Primer
Basement Proofer - CBP (Custom Building Products), RedGard
Waterproofing & Crack Prevention Floor Leveler - CBP Level Quik
Limitations/Exclusions These types of installations will NOT be covered under warranty:
All exterior installations & seasonal porches, boats/campers/
RV's, sunrooms/solariums
Steam Cleaner DO NOT USE
Vertical Surfaces Not covered under warranty. Can be done using high quality
construction adhesive. Product not intended for this usage
Add:Hexing Street, Jinfeng Town, Zhangjiagang City, Jiangsu Province
COPYRIGHT@ 2020 ELETILE 苏ICP备14024213号-1 DigItal By VTHINK
Brand story| Products| Join us
Add:Hexing Street, Jinfeng Town, Zhangjiagang City, Jiangsu Province
Copyright © 2020. ELETILE 苏ICP备14024213号-1 BY VTHINK